File: 268_SGLI_TOTAL_LUTOPKL01.MAT 26 Variables, 57 Data Points FhdS 1: MOBY268 SGLI Total - MODELED KL - Band Averaged Data File FhdS 2: Dir: D:\ZFLORA\MLDATA\MOBY\DATA\MOBY268\PRECALS FhdS 3: Using a modeled KL01 to remove inelastic processes from Lw and Lwn2 FhdS 4: DATA INCLUDED: Good and Questionable Data FhdS 5: PROCESSING: Oct 2016 FhdS 6: All data are STRAY LIGHT CORRECTED with version 6.1 FhdS 7: DATE CREATED: 08-Jun-2020 22:31:00 FhdS 8: ##Oct 2016 reprocessing applied on 08-Jun-2020 22:31:00 ------------------------------------------- ##MODELED KL: Band weighted modeled Kl data, missing data means the program was not able to calculate a model for that MOBY file and Lw ##0.234 meters added to the MOBY arm depths ##No shift in the Lu RSG data was needed DscS 1: Year DscS 2: Julian Day DscS 3: GMT Time (HH.hh) DscS 4: Observation Date (YYMMDD.HHMMmm) DscS 5: MOBY deployment DscS 6: Latitide (DD.MMmm) (+N/-S) DscS 7: Longitide (DD.MMmm) (-W/+E) DscS 8: Data Status (1 = Good and 2 = Questionable) DscS 9: SGLI Water Leaving Radiance RSR_VN01 Band 1 380 nm (µW/cm²/sr) DscS 10: SGLI Water Leaving Radiance RSR_VN02 Band 2 412 nm (µW/cm²/sr) DscS 11: SGLI Water Leaving Radiance RSR_VN03 Band 3 443 nm (µW/cm²/sr) DscS 12: SGLI Water Leaving Radiance RSR_VN04 Band 4 490 nm (µW/cm²/sr) DscS 13: SGLI Water Leaving Radiance RSR_VN05 Band 5 529 nm (µW/cm²/sr) DscS 14: SGLI Water Leaving Radiance RSR_VN06 Band 6 566 nm (µW/cm²/sr) DscS 15: SGLI Water Leaving Radiance RSR_VN07 Band 7 672 nm (µW/cm²/sr) DscS 16: SGLI Water Leaving Radiance RSR_VN08 Band 8 672 nm (µW/cm²/sr) DscS 17: SGLI Water Leaving Radiance RSR_P01 Band 12 672 nm (µW/cm²/sr) DscS 18: SGLI Solar Norm Water Leaving Rad 2 RSR_VN01 Band 1 380 nm (µW/cm²/sr) DscS 19: SGLI Solar Norm Water Leaving Rad 2 RSR_VN02 Band 2 412 nm (µW/cm²/sr) DscS 20: SGLI Solar Norm Water Leaving Rad 2 RSR_VN03 Band 3 443 nm (µW/cm²/sr) DscS 21: SGLI Solar Norm Water Leaving Rad 2 RSR_VN04 Band 4 490 nm (µW/cm²/sr) DscS 22: SGLI Solar Norm Water Leaving Rad 2 RSR_VN05 Band 5 529 nm (µW/cm²/sr) DscS 23: SGLI Solar Norm Water Leaving Rad 2 RSR_VN06 Band 6 566 nm (µW/cm²/sr) DscS 24: SGLI Solar Norm Water Leaving Rad 2 RSR_VN07 Band 7 672 nm (µW/cm²/sr) DscS 25: SGLI Solar Norm Water Leaving Rad 2 RSR_VN08 Band 8 672 nm (µW/cm²/sr) DscS 26: SGLI Solar Norm Water Leaving Rad 2 RSR_P01 Band 12 672 nm (µW/cm²/sr) Xdat: Year, JDay, GMTTime, ObsDate,Deploy, Lat, Long, ?Data, RSR_VN01, RSR_VN02, RSR_VN03, RSR_VN04, RSR_VN05, RSR_VN06, RSR_VN07, RSR_VN08, RSR_P01, RSR_VN01, RSR_VN02, RSR_VN03, RSR_VN04, RSR_VN05, RSR_VN06, RSR_VN07, RSR_VN08, RSR_P01 2019, 276, 0.2687,191003.0016, 268, 20.4855, -157.1169, 2, 1.0912, 1.6534, 1.3395, 0.8589, 0.2868, 0.1416, 0.0122, 0.0122, 0.0122, 1.6263, 2.2386, 1.8094, 1.1327, 0.3723, 0.1870, 0.0157, 0.0157, 0.0157 2019, 289, 0.2682,191016.0016, 268, 20.4856, -157.1115, 2, 1.0661, 1.6409, 1.3400, 0.8316, 0.2683, 0.1319, 0.0109, 0.0108, 0.0109, 1.7824, 2.4940, 2.0341, 1.2322, 0.3915, 0.1961, 0.0156, 0.0156, 0.0157 2019, 294, 0.2692,191021.0016, 268, 20.4874, -157.1095, 2, 1.0729, 1.5786, 1.2540, 0.7954, 0.2622, 0.1287, 0.0106, 0.0106, 0.0106, 1.8987, 2.5608, 2.0430, 1.2713, 0.4140, 0.2077, 0.0167, 0.0166, 0.0167 2019, 295, 0.2598,191022.0016, 268, 20.4851, -157.1167, 1, 0.9457, 1.4371, 1.1649, 0.7586, 0.2552, 0.1264, 0.0109, 0.0109, 0.0109, 1.6002, 2.2068, 1.7838, 1.1329, 0.3752, 0.1892, 0.0158, 0.0158, 0.0158 2019, 297, 0.2700,191024.0016, 268, 20.4899, -157.1080, 1, 0.9250, 1.4286, 1.1672, 0.7676, 0.2652, 0.1328, 0.0117, 0.0117, 0.0117, 1.5733, 2.1945, 1.7825, 1.1395, 0.3866, 0.1969, 0.0167, 0.0167, 0.0168 2019, 298, 0.2677,191025.0016, 268, 20.4861, -157.1101, 1, 0.9371, 1.4302, 1.1519, 0.7451, 0.2532, 0.1269, 0.0115, 0.0114, 0.0115, 1.7194, 2.3884, 1.9216, 1.2141, 0.4062, 0.2073, 0.0181, 0.0181, 0.0182 2019, 299, 0.2675,191026.0016, 268, 20.4849, -157.1157, 1, 0.7678, 1.1297, 0.9565, 0.7086, 0.2784, 0.1455, 0.0127, 0.0127, 0.0128, 1.4558, 1.9532, 1.6532, 1.1976, 0.4636, 0.2470, 0.0209, 0.0209, 0.0209 2019, 301, 0.2740,191028.0016, 268, 20.4923, -157.1197, 1, 0.8784, 1.3655, 1.1199, 0.7399, 0.2534, 0.1260, 0.0111, 0.0111, 0.0111, 1.4604, 2.0412, 1.6586, 1.0628, 0.3574, 0.1808, 0.0154, 0.0154, 0.0154 2019, 302, 0.2678,191029.0016, 268, 20.4956, -157.1168, 1, 0.9263, 1.4028, 1.1370, 0.7425, 0.2536, 0.1260, 0.0110, 0.0110, 0.0110, 1.5587, 2.1293, 1.7137, 1.0865, 0.3645, 0.1844, 0.0155, 0.0155, 0.0155 2019, 304, 0.2675,191031.0016, 268, 20.4912, -157.1200, 1, 0.8702, 1.3295, 1.0840, 0.7209, 0.2497, 0.1243, 0.0109, 0.0109, 0.0109, 1.4892, 2.0508, 1.6594, 1.0716, 0.3651, 0.1852, 0.0155, 0.0155, 0.0155 2019, 306, 0.2747,191102.0016, 268, 20.4897, -157.1201, 2, 0.9077, 1.3895, 1.1257, 0.7478, 0.2616, 0.1305, 0.0123, 0.0123, 0.0123, 1.6045, 2.2138, 1.7787, 1.1470, 0.3942, 0.2002, 0.0182, 0.0182, 0.0182 2019, 308, 0.2708,191104.0016, 268, 20.4933, -157.1193, 1, 1.0023, 1.4994, 1.1894, 0.7517, 0.2501, 0.1233, 0.0114, 0.0114, 0.0114, 1.7995, 2.4336, 1.9207, 1.1809, 0.3866, 0.1942, 0.0173, 0.0173, 0.0173 2019, 309, 0.2708,191105.0016, 268, 20.4932, -157.1189, 1, 0.9037, 1.3430, 1.0844, 0.7145, 0.2482, 0.1235, 0.0114, 0.0114, 0.0114, 1.6381, 2.1977, 1.7636, 1.1299, 0.3862, 0.1956, 0.0174, 0.0174, 0.0175 2019, 314, 0.2677,191110.0016, 268, 20.4929, -157.1086, 1, 1.0286, 1.5683, 1.2805, 0.7766, 0.2467, 0.1201, 0.0097, 0.0097, 0.0097, 1.8477, 2.5343, 2.0499, 1.2044, 0.3758, 0.1863, 0.0144, 0.0144, 0.0144 2019, 315, 0.2702,191111.0016, 268, 20.4947, -157.1105, 1, 0.9531, 1.4203, 1.1304, 0.7220, 0.2391, 0.1173, 0.0103, 0.0103, 0.0103, 1.7244, 2.3084, 1.8186, 1.1249, 0.3658, 0.1826, 0.0154, 0.0154, 0.0154 2019, 317, 0.2712,191113.0016, 268, 20.4914, -157.1101, 1, 0.8952, 1.3557, 1.0862, 0.6918, 0.2277, 0.1113, 0.0091, 0.0091, 0.0092, 1.6994, 2.3095, 1.8304, 1.1270, 0.3635, 0.1806, 0.0142, 0.0142, 0.0143 2019, 318, 0.2598,191114.0016, 268, 20.4891, -157.1089, 1, 0.9587, 1.4453, 1.1533, 0.7289, 0.2424, 0.1203, 0.0109, 0.0108, 0.0109, 1.8203, 2.4681, 1.9494, 1.1933, 0.3891, 0.1961, 0.0168, 0.0168, 0.0169 2019, 319, 0.2675,191115.0016, 268, 20.4923, -157.1101, 1, 0.9646, 1.4750, 1.1761, 0.7274, 0.2326, 0.1139, 0.0098, 0.0097, 0.0098, 1.9015, 2.6214, 2.0738, 1.2440, 0.3906, 0.1943, 0.0160, 0.0159, 0.0160 2019, 324, 0.2693,191120.0016, 268, 20.4877, -157.1090, 2, 0.9051, 1.3836, 1.1020, 0.6956, 0.2307, 0.1138, 0.0106, 0.0106, 0.0107, 2.1003, 2.9459, 2.3598, 1.4642, 0.4814, 0.2436, 0.0219, 0.0219, 0.0220 2019, 329, 0.2678,191125.0016, 268, 20.4915, -157.1080, 1, 0.7958, 1.1969, 0.9788, 0.6576, 0.2339, 0.1177, 0.0117, 0.0117, 0.0117, 1.5341, 2.0632, 1.6630, 1.0778, 0.3759, 0.1924, 0.0181, 0.0181, 0.0181