Campbell Time Series

The Campbell data logger controls MOBYs functional timing. It turns on the Falcon controller computer which will do a task depending upon the time it is powered up. The Campbell is also programed to power down the buoy at programmable times to make sure the system is shutdown at least once per day to return the system to a known state. The Falcon always boots from a cold state at power up. The Campbell operates based on a proprietary CRBasic programing language. Campbell analog Inputs measure Battery voltage, Campbell unit panel temperature, Case Air Temperature, Case Humidity, state of the Falcon Main Power Relay and state of the Charge Relay. Campbell has override control of the Main Power Relay and the Charge Relay. Campbell modem power is also controlled by the Campbell. The Campbell data table contains a record of the above parameters as well as important program flow flags. The voltage monitored by the Campbell is actually the voltage of the Campbell backup battery which is diode isolated from the Campbell and the Upper Battery. Due to the isolated battery supplies, this voltage is not much use in quantitatively monitoring the health of the Upper Battery. The Campbell backup battery only powers the Campbell when the Upper Battery falls below about 11.5 volts. The Campbell will operate down to a voltage of 10.5 volts at which point it will only try to switch the Charge Really to the Upper Battery to try and gain power for the controller rather than any lower batteries.

MainRlyState, 0=False=Off -1=True=On
ChargeRlyState, 0=False=Down -1=True=Up
MainRlyState is the feedback from the power relay controlling the Falcon
ChargeRlyState is the feedback from the charge relay that switches the PV power to the Upper or Lower batteries
kohms is a flooding sensor, it will go below 10K if the housing contains free water
Campbell battery = BattV
Solar panel (PhotoVoltaic cell) voltage = PVVolts


Reading for the last day of the file: 31-Oct-2021 23:59:00 to 30-Oct-2021 23:59:00 (1 day)
Measurment Mean Min Max %std
CamBattV (Volts 11.8242 11.12 12.85 2.54
PTemp_C (Deg C) 26.1892 24.44 28.31 4.78
AirTC (Deg C) 26.3953 24.45 28.75 5.23
RH (%) 40.2672 39.12 41.92 1.16
Measurment Minutes Down Minutes Up
ChargeRlyState 3.4 20.6167
Measurment Minutes Off Minutes On
MainRlyState 21.3833 2.6333

Means for the last 10 days for each day in the file (times and days from GMT time)
Day BattV PTemp_C AirTC RH kohms
21-Oct-2021 11.8132 25.5321 25.9035 40.0265
22-Oct-2021 12.0905 26.0396 26.0066 40.6272
23-Oct-2021 11.795 26.222 26.1376 41.3466
24-Oct-2021 11.5778 26.0654 26.0074 41.3292
25-Oct-2021 11.6151 26.0914 25.9593 41.4433
26-Oct-2021 11.6241 26.0178 26.1235 41.2908
27-Oct-2021 11.7857 26.0244 26.3199 40.331
28-Oct-2021 11.8515 26.0518 25.9506 41.0094
29-Oct-2021 11.822 26.0541 26.1395 40.6675
30-Oct-2021 11.8575 25.6213 25.7234 40.8427
31-Oct-2021 11.8241 26.1891 26.395 40.2663

Campbell Start and Stop Times for turning on (last 20 cycles) - MainRlyState = -1
On/Off Start Time Stop Time Delta Time (hours)
Off 30-Oct-2021 17:16:00 30-Oct-2021 17:59:00 0.72
On 30-Oct-2021 18:00:00 30-Oct-2021 18:17:00 0.28
Off 30-Oct-2021 18:18:00 30-Oct-2021 20:35:00 2.28
On 30-Oct-2021 20:36:00 30-Oct-2021 20:51:00 0.25
Off 30-Oct-2021 20:52:00 30-Oct-2021 22:07:00 1.25
On 30-Oct-2021 22:08:00 30-Oct-2021 22:23:00 0.25
Off 30-Oct-2021 22:24:00 30-Oct-2021 23:44:00 1.33
On 30-Oct-2021 23:45:00 31-Oct-2021 00:23:00 0.63
Off 31-Oct-2021 00:24:00 31-Oct-2021 02:59:00 2.58
On 31-Oct-2021 03:00:00 31-Oct-2021 03:15:00 0.25
Off 31-Oct-2021 03:16:00 31-Oct-2021 03:59:00 0.72
On 31-Oct-2021 04:00:00 31-Oct-2021 04:15:00 0.25
Off 31-Oct-2021 04:16:00 31-Oct-2021 16:59:00 12.72
On 31-Oct-2021 17:00:00 31-Oct-2021 17:15:00 0.25
Off 31-Oct-2021 17:16:00 31-Oct-2021 17:59:00 0.72
On 31-Oct-2021 18:00:00 31-Oct-2021 18:15:00 0.25
Off 31-Oct-2021 18:16:00 31-Oct-2021 20:35:00 2.32
On 31-Oct-2021 20:36:00 31-Oct-2021 21:13:00 0.62
Off 31-Oct-2021 21:14:00 31-Oct-2021 22:07:00 0.88
On 31-Oct-2021 22:08:00 31-Oct-2021 22:23:00 0.25
Off 31-Oct-2021 22:24:00 31-Oct-2021 23:44:00 1.33

Start and Stop Times for when Falcon switches the Charge Relay (last 20 cycles) - ChargeRlyState = -1
Up/Down Start Time Stop Time Delta Time (hours)
Up 30-Oct-2021 03:13:00 30-Oct-2021 17:13:00 14.00
Down 30-Oct-2021 17:14:00 30-Oct-2021 18:01:00 0.78
Up 30-Oct-2021 18:02:00 30-Oct-2021 18:12:00 0.17
Down 30-Oct-2021 18:13:00 30-Oct-2021 18:13:00 0.00
Up 30-Oct-2021 18:14:00 30-Oct-2021 18:14:00 0.00
Down 30-Oct-2021 18:15:00 30-Oct-2021 20:37:00 2.37
Up 30-Oct-2021 20:38:00 30-Oct-2021 22:19:00 1.68
Down 30-Oct-2021 22:20:00 30-Oct-2021 22:20:00 0.00
Up 30-Oct-2021 22:21:00 30-Oct-2021 22:21:00 0.00
Down 30-Oct-2021 22:22:00 30-Oct-2021 23:46:00 1.40
Up 30-Oct-2021 23:47:00 31-Oct-2021 03:11:00 3.40
Down 31-Oct-2021 03:12:00 31-Oct-2021 03:12:00 0.00
Up 31-Oct-2021 03:13:00 31-Oct-2021 17:11:00 13.97
Down 31-Oct-2021 17:12:00 31-Oct-2021 17:12:00 0.00
Up 31-Oct-2021 17:13:00 31-Oct-2021 18:13:00 1.00
Down 31-Oct-2021 18:14:00 31-Oct-2021 20:37:00 2.38
Up 31-Oct-2021 20:38:00 31-Oct-2021 21:09:00 0.52
Down 31-Oct-2021 21:10:00 31-Oct-2021 21:10:00 0.00
Up 31-Oct-2021 21:11:00 31-Oct-2021 21:12:00 0.02
Down 31-Oct-2021 21:13:00 31-Oct-2021 22:09:00 0.93
Up 31-Oct-2021 22:10:00 31-Oct-2021 23:59:00 1.82